Connectathon 11 Snapshot

This page is part of the FHIR Specification (v1.2.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Uslab\spec-uslab-example2.json

Raw JSON (canonical form)

USLab Specimen Profile Example: Urine- first catch

{
  "resourceType": "Specimen",
  "id": "spec-uslab-example2",
  "text": {
    "fhir_comments": [
      "   a specimen identifier - e.g. assigned when the specimen was taken by the orderer/placer  use the accession number for the filling lab   ",
      "  Placer ID  "
    ],
    "status": "generated",
    "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: spec-uslab-example2</p><p><b>identifier</b>: SID456 (OFFICIAL)</p><p><b>type</b>: Urine, First Void <span>(Details : {SNOMED CT code '698276005' = '698276005', given as 'First stream urine sample'}; {http://ehr.goodhealthclinic.org code 'UFV' = '??', given as 'Urine, First Void'})</span></p><p><b>subject</b>: <a>Todd Lerr</a></p><p><b>accessionIdentifier</b>: 21041205000001 (OFFICIAL)</p><h3>Collections</h3><table><tr><td>-</td><td><b>Collected[x]</b></td></tr><tr><td>*</td><td>05/12/2014</td></tr></table></div>"
  },
  "identifier": [
    {
      "use": "official",
      "system": "http://ehr.goodhealthclinic.org/identifiers/specimen",
      "value": "SID456"
    }
  ],
  "type": {
    "fhir_comments": [
      "  Filler ID moved to accsession number\n\t<identifier>\n\t\t<use value=\"official\"></use>\n\t\t<label  value=\"Filler Specimen ID\"></label>\n\t\t<system value=\"http://lis.acmelabs.org/identifiers/specimen\"/>\n\t\t<value value=\"SID456\"/>\n\t</identifier>\n  ",
      "  \n   Type is a loosely defined field because there is such a lot of variation in how it is used.\n   The principal variation is how much information that could be represented elsewhere is also\n   represented here. For instance, here's some possible types:\n     lithium heparin plasma   (+ .container.additive) (e.g. SNOMED CT 446272009)\n     transfusion bag of blood (+ container.type)\n     Peritoneal lavage        (+ collection.bodySite)\n   If the type includes other fields, it would be normal not to populate the other fields\n\n   Note that this practice is so widespread that it's pointless to try and stop it  :(   ",
      "  choice of SNOMED CT concept code...  "
    ],
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "698276005",
        "_code": {
          "fhir_comments": [
            "  EH: Note to balloters  - lots of choices for uriine but this is best for Aptima 2 GC-CT  "
          ]
        },
        "display": "First stream urine sample"
      },
      {
        "fhir_comments": [
          "   and or local code  "
        ],
        "system": "http://ehr.goodhealthclinic.org",
        "code": "UFV",
        "display": "Urine, First Void"
      }
    ],
    "text": "Urine, First Void"
  },
  "subject": {
    "fhir_comments": [
      "  Patient is required from core   "
    ],
    "reference": "Patient/patient-uslab-example1",
    "display": "Todd Lerr"
  },
  "accessionIdentifier": {
    "fhir_comments": [
      "   accession identifier - e.g. assigned by the labaratory when it is received.\n     This is common, unlike specimen identifier   "
    ],
    "use": "official",
    "system": "http://lis.acmelabs.org/identifiers/accession",
    "value": "21041205000001"
  },
  "collection": {
    "collectedDateTime": "2014-12-05",
    "_collectedDateTime": {
      "fhir_comments": [
        "   the time of collection is required. Usually a point in time, but can be a period\n      (collectedPeriod) if it's a timed collection (e.g. a 24 hour urine)   "
      ]
    }
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.